Total Nickel (Ni-Ion) On-Line Analyzer Total Nickel On-Line Analyzer Water Quality Heavy Metal Analyzer Model: R-Total Nickel Measurement method: dimethylglyoxime (dimethylglyoxime) spectrophotometric test range: (0-0.5) mg/l, (0-2) mg/l, (0-5) mg/l, ( 0-20)mg/l four-speed range automatic switching detection offline: 0.005mg/l
"Gravity Die Casting. A permanent mould casting process, where the molten metal is poured from a vessle of ladle into the mould, and cavity fills with no force other than gravity, in a similar manner to the production of sand castings, although filling cn be controlled by tilting the die."
Sometimes referred to as Permanent Mould, GDC is a repeatable casting process used for non-ferrous alloy parts, typically aluminium, Zinc and Copper Base alloys.
The process differs from HPDC in that Gravity- rather than high pressure- is used to fill the mould with the liquid alloy.
GDC is suited to medium to high volumes products and typically parts are of a heavier sections than HPDC, but thinner sections than sand casting.
There are three key stages in the process.
Advantages
Gravity Casting Parts,Aluminum Alloy Gravity Casting Parts,Aluminum Gravity Die Casting Parts,Gravity Casting Aluminum Parts HSI INDUSTRIEL LTD , http://www.hsiindustriel.com
Resolution: <0.002mg/l
Accuracy: standard solution <5%; water sample <10%
Reproducibility: < 5%
Measurement period: 30min, can be set without failure Running time: ≧ 720h / second span drift: ± 5% FS
Sample interval: continuous, 1 hour, 2 hours. . . 24 hours, triggering, and specified time point correction interval: Manually or automatically at a selected interval and time (1-7 days)
Cleaning interval: manually or automatically at selected intervals and times (1-7 days)
Maintenance interval:> 1 month, about 1 hour each time Reagent consumption: about 720 samples per set of man-machine interface: 7-inch, 70,000 colors, 800*480 resolution, TFT true color touch screen printing: Reserved printer Interface, external industrial micro printer (optional)
Storage: 20,000 data, no power loss, full automatic coverage of the oldest data (up to 40,000 data can be added)
Communication interface: 1 RS232 digital interface or RS485, support MODBUS communication protocol or custom protocol
1 channel analog 4-20mA (20mA corresponding range adjustable)
Pre-treatment system: self-cleaning, back blowing, and precision filtration functions ensure that the sample is well representative while avoiding clogging of pipelines with large suspended particles (optional)
Dimensions 900×600×450(mm) Weight 50kg
Power supply AC 220V ± 20%, 50Hz ± 1% power 300W
Ambient temperature 5 to 40°C Ambient humidity ≤85%
Gravity Die Casting